MOOSEN PRODUCT PORTFOLIO
Platinum–Iridium Components and Medical Device Subassemblies
Find the MOOSEN product or customer-defined assembly closest to your design. Each page explains the intended function, specification fields, production considerations and information needed for an RFQ.

MOOSEN PRODUCT FILM
Precision in Every Connection
Explore MOOSEN’s medical components, production and inspection in 30 seconds.
01 / RADIOPAQUE COMPONENTS
Marker and precision metal components
Choose a marker form by its role in the device: a shaft-mounted band, a ring, a disc, a perforated ring or a custom Pt–Ir part. Selected standard marker-ring sizes may be available; custom dimensions and attachment are confirmed from the drawing.
Platinum–iridium marker rings
Radiopaque Pt–Ir rings and miniature tubular forms for imaging and device integration.
Explore Platinum–iridium marker rings →
Platinum–iridium marker bands
Bands specified for shaft fit, marker location and joining method. Compare bands, rings and discs in our radiopaque marker selection guide.
Explore Platinum–iridium marker bands →
Custom catheter marker bands
Drawing-defined catheter bands when a standard geometry does not fit.
Platinum–iridium marker discs
Disc markers considered for placement, retention and radiographic function.
Explore Platinum–iridium marker discs →
Platinum–iridium perforated rings
Perforated ring forms reviewed for hole geometry, integrity and assembly.
Explore Platinum–iridium perforated rings →
Custom platinum–iridium parts
Precision parts shaped around the customer’s device interface.
02 / MEDICAL CONDUCTORS
Platinum–iridium wire and insulated conductors
For medical conductors, MOOSEN supplies bare Pt–Ir wire, ETFE-coated wire and coaxial DFT composite wire. Material construction, geometry and insulation are specified by product and drawing.
Platinum iridium wire supplier
Procurement-focused Pt–Ir wire sourcing, specification and documentation.
Explore Platinum iridium wire supplier →
Custom platinum–iridium medical wire
Medical conductor dimensions and condition aligned to a device assembly.
ETFE-coated medical wire
ETFE-coated wire with a specified Pt–Ir, DFT or 316L base conductor.
03 / IMPLANTABLE CONNECTIONS
Connection components
The electrical and mechanical interfaces determine the component. Review contact geometry, joining, insulation boundaries and hermetic interfaces together.
Implantable contact modules
Compact contact assemblies for customer-defined implantable interfaces.
Medical hermetic feedthrough components
Miniature hermetic feedthrough assemblies with specified housing, ceramic and conductor construction.
04 / SENSOR COMPONENTS
Medical sensor component pathways
MOOSEN supplies temperature sensors and ultra-fine temperature-sensing leads. Construction and acceptance are specified for the application.
Temperature sensors and thermocouples
Custom temperature-sensing assemblies, including thermocouple designs.
Explore Temperature sensors and thermocouples →
MRI-compatible temperature sensors
Component-level material and verification review for radiation-exposed designs.
Ultra-fine sensor components
Ultra-fine temperature-sensing leads with thermocouple, NTC or RTD options.
05 / ELECTRODE LEAD COMPONENTS
Electrode and lead component forms
MOOSEN supplies finished electrode leads as well as contacts and conductors. Lead bodies, contact patterns and verification follow the customer’s device design.
Paddle, cylindrical and directional lead components
Finished paddle, cylindrical and directional leads or specified components.
Explore Paddle, cylindrical and directional lead components →
Flexible, cuff and membrane electrode components
Finished flexible, cuff and membrane leads or specified components.
Explore Flexible, cuff and membrane electrode components →
Platinum–iridium electrode rings
Electrical contact rings specified around exposed area and conductor connection.
Sensing and diagnostic lead components
Customer-designed sensing and diagnostic electrode leads.
Explore Sensing and diagnostic lead components →
Electrode extension lead components
Customer-designed extension leads and connection components.
PRODUCT SUPPORT
Frequently asked questions
Are the listed components standard sizes?
Most MOOSEN medical components are manufactured to the buyer’s drawing. Dimensions, alloy grade and inspection criteria are confirmed for each part number.
Can several component types be sourced together?
MOOSEN can quote platinum-iridium rings, marker bands, wire and contact parts within one customer program as separate controlled items.
Can I order prototype quantities?
MOOSEN can quote sample quantities for assembly evaluation, followed by repeat production against the approved specification.
What should I include in a product RFQ?
Send the current drawing revision, Pt-Ir grade, tolerances, quantity, joining context and required material or inspection records.
Send a drawing for a component review
Include the part drawing or preliminary sketch, Pt–Ir material requirement, application, mating features, target volume and inspection or documentation needs. MOOSEN can identify the right product pathway and the next technical questions.